iiPower Xplus 3KVA/48v Inverter - Transformer based Inverter

  • Pure sine wave inverter output waveform for smooth operation of appliances
  • In-built Transformer which offers more protection and guarantees good workability on inductive and capacitive loads
  • Green inverter with solar input priority
  • Compatible with mains voltage and generator power
  • Built-in battery equalization function to prevent sulphation in batteries for optimized battery performance and increased battery life-cycle
  • Selectable input voltage range (wide or narrow) based on usage and home appliances
  • User-friendly LCD with setting function for easy inverter operation
  • Selectable Inverter or UPS battery input mode based on load type
  • Multiple protection:

Ø Over voltage protection: Shut down output when the voltage is above 285+/-10V

Ø Under voltage protection: Shut down output when the voltage is below 120+/-10V

Ø Over temperature protection: When heatsink temperature exceeds 90C: Shuts down charger in mains mode, and shut down inverter in battery mode

Ø Short circuit protection: Shut down output

Ø Overload capacity (precision: +/-10%):

1. Mains mode:

1) 100% load, long term operation

2) 100~120% shut down output after 3min, re-startup automatically after 30s, after re-startup 3 times, if the overload still exists, then it enters failure mode and the unit needs to be started up manually

3) 120~130% shut down output after 30s, re-startup automatically after 30s, after re-startup 3 times, if the overload still exists, then it enters failure mode and the unit needs to be started up manually

4) ≥130% shut down output immediately, re-startup automatically after 30s, after re-startup 3 times, if the overload still exists, then it enters failure mode and the unit needs to be started up manually

2. Battery mode:

1) 100% load, long term operation

2) 100~110% shut down output after 10s, re-startup automatically after 30s (with soft startup), after re-startup 3 times, if the overload still exists, then it enters failure mode and the unit needs to be started up manually

3) ≥110% shut down output immediately, re-startup automatically after 30s (with soft startup), after re-startup 3 times, if the overload still exists, then it enters failure mode and the unit needs to be started up manually